Bis zu 50 % günstiger als neu 3 Jahre rebuy Garantie Professionelles Refurbishment
ElektronikMedien
Tipps & News
AppleAlle anzeigen
TabletsAlle anzeigen
HandyAlle anzeigen
Fairphone
AppleAlle anzeigen
iPhone Air Generation
GoogleAlle anzeigen
Pixel Fold
HonorAlle anzeigen
HuaweiAlle anzeigen
Honor SerieY-Serie
NothingAlle anzeigen
OnePlusAlle anzeigen
OnePlus 11 GenerationOnePlus 12 Generation
SamsungAlle anzeigen
Galaxy XcoverWeitere Modelle
SonyAlle anzeigen
Weitere Modelle
XiaomiAlle anzeigen
Weitere Modelle
Tablets & eBook ReaderAlle anzeigen
Google
AppleAlle anzeigen
HuaweiAlle anzeigen
MatePad Pro Serie
MicrosoftAlle anzeigen
XiaomiAlle anzeigen
Kameras & ZubehörAlle anzeigen
ObjektiveAlle anzeigen
System & SpiegelreflexAlle anzeigen
WearablesAlle anzeigen
Fitness TrackerAlle anzeigen
SmartwatchesAlle anzeigen
Xiaomi
Konsolen & ZubehörAlle anzeigen
Lenovo Legion GoMSI Claw
NintendoAlle anzeigen
Nintendo Switch Lite
PlayStationAlle anzeigen
XboxAlle anzeigen
Audio & HiFiAlle anzeigen
KopfhörerAlle anzeigen
FairphoneGoogle
LautsprecherAlle anzeigen
Beats by Dr. DreGoogleYamahatonies
iPodAlle anzeigen

Handgeprüfte Gebrauchtware

Bis zu 50 % günstiger als neu

Der Umwelt zuliebe

Heat exchanger failure investigation report

Ataliba Miguel (Taschenbuch, Englisch)

Keine Bewertungen vorhanden
Optischer Zustand
Beschreibung
Technical Report from the year 2013 in the subject Materials Science, grade: B, Robert Gordon University Aberdeen, course: MSc Oil and Gas Engineering, language: English, abstract: A high pressure gas cooler located in an offshore platform have been operating for more than 10 years. Throughout that period the gas cooler have been subjected to several tube failures, the failures have caused gas leak from the tube side. Several materials upgrades have been used to contain the tube failure. The last choice was to use a more corrosion resistant material Hastelloy C22. Crevice corrosion has been reported as the primary failure mechanism. The tube and tube plate joined surfaces have been exposed to high temperature which is relatively higher than the critical crevice temperature of Hastelloy C22. There was a poor heat transfer between the shell side fluid and tube side due to a small heat transfer area and low fluid velocity in the affected zone. Stress corrosion and fatigue corrosion accounted for the secondary failure mechanism which ultimately caused a crack in the tubes. Other possible reason identified to cause crevice corrosion was the mechanical rolling expansion technique. Oftentimes it creates rear crevices on the tubes with enough geometry to develop crevice chemistry. Mitigation methods such as hydraulic expansion technique, heat treatment for residual stresses and baffle design enhancements have been proposed in this report. Key words: shell and tube heat exchanger failure; Hastelloy C22 material; tube failure; localized corrosion; crevice corrosion; internal pitting corrosion
17,95 €
Taschenbuch | Neu

oder

Auf Lager Versandbereit in 1-2 Werktagen
zzgl.

Du kannst wie immer einen Kaufalarm setzen, wenn du auf das gebrauchte Buch warten möchtest.

Auf Lager Versandbereit in 1-2 Werktagen
zzgl.

Handgeprüfte Gebrauchtware

Bis zu 50 % günstiger als neu

Der Umwelt zuliebe

Technische Daten


Erscheinungsdatum
01.01.2014
Sprache
Englisch
EAN
9783656611752
Herausgeber
GRIN Verlag
Autor
Ataliba Miguel
Seitenanzahl
24
Auflage
1
Einbandart
Taschenbuch
Höhe
210 mm
Breite
14.8 cm

Warnhinweise und Sicherheitsinformationen

Informationen nach EU Data Act

-.-
Leider noch keine Bewertungen
Leider noch keine Bewertungen
Schreib die erste Bewertung für dieses Produkt!
Wenn du eine Bewertung für dieses Produkt schreibst, hilfst du allen Kund:innen, die noch überlegen, ob sie das Produkt kaufen wollen. Vielen Dank, dass du mitmachst!