Bis zu 50 % günstiger als neu 3 Jahre rebuy Garantie Professionelles Refurbishment
ElektronikMedien
Tipps & News
AppleAlle anzeigen
TabletsAlle anzeigen
HandyAlle anzeigen
Fairphone
AppleAlle anzeigen
iPhone Air Generation
GoogleAlle anzeigen
Pixel Fold
HonorAlle anzeigen
HuaweiAlle anzeigen
Honor SerieY-Serie
NothingAlle anzeigen
OnePlusAlle anzeigen
OnePlus 11 GenerationOnePlus 12 Generation
SamsungAlle anzeigen
Galaxy XcoverWeitere Modelle
SonyAlle anzeigen
Weitere Modelle
XiaomiAlle anzeigen
Weitere Modelle
Tablets & eBook ReaderAlle anzeigen
Google
AppleAlle anzeigen
HuaweiAlle anzeigen
MatePad Pro Serie
MicrosoftAlle anzeigen
XiaomiAlle anzeigen
Kameras & ZubehörAlle anzeigen
ObjektiveAlle anzeigen
System & SpiegelreflexAlle anzeigen
WearablesAlle anzeigen
Fitness TrackerAlle anzeigen
SmartwatchesAlle anzeigen
Xiaomi
Konsolen & ZubehörAlle anzeigen
Lenovo Legion GoMSI Claw
NintendoAlle anzeigen
Nintendo Switch Lite
PlayStationAlle anzeigen
XboxAlle anzeigen
Audio & HiFiAlle anzeigen
KopfhörerAlle anzeigen
FairphoneGoogle
LautsprecherAlle anzeigen
Beats by Dr. DreGoogleYamahatonies
iPodAlle anzeigen

Handgeprüfte Gebrauchtware

Bis zu 50 % günstiger als neu

Der Umwelt zuliebe

Fallfilmverdampfung viskoser Reinstoffe unter Berücksichtigung der Einlaufgeometrie

Stefanie Arndt (Unbekannter Einband, Deutsch)

Keine Bewertungen vorhanden
Optischer Zustand
Beschreibung
Gegenstand der vorliegenden Arbeit ist die Fallfilmverdampfung viskoser Reinstoffe mit besonderem Fokus auf die Einlaufgeometrie. Zur Messung des Wärmeübergangs wurde ein Einrohr-Fallfilmverdampfer aus Edelstahl aufgebaut und betrieben. Der Wärmeübergang wurde mit Wasser und den viskosen Medien Propylenglykol und Cyclohexanol untersucht. Zur Variation der Einlaufgeometrie dienten ein Glattwehr und ein Turmwehr. Außerdem wurde die Fluiddynamik des Rieselfilms in Abhängigkeit von der Einlaufgeometrie im oberen Bereich einer unbeheizten Anlage untersucht. Eine computergestützte Methode zur Auswertung von fotografischen Aufnahmen wurde entwickelt, um die Fluiddynamik von Wasser/ Polyvinylpyrrolidon Lösungen zu analysieren. Die Ergebnisse der Experimente zum Wärmeübergang zeigen, dass für viskose Medien die Korrelationen nach VDI Wärmeatlas [Schnabel et al., 2006, Abschnitt Md] nicht hinreichend zuverlässig sind. Ebenso können die Korrelationen nach Alhusseini [Alhusseini, 1995] und Weise [Weise, 2007], die für viskose Medien entwickelt wurden, die experimentell ermittelte Nusselt-Zahl sowohl qualitativ als auch quantitativ nicht zufriedenstellend beschreiben. Die Wärmeübergangsmessungen lassen erkennen, dass die Geometrie der Anlage, speziell die Einlaufgeometrie einen signifikanten Einfluss auf den integralen Wärmeübergangskoeffizienten bei der Verdampfung viskoser Medien hat. Durch den Einsatz des Turmwehrs konnte der Wärmeübergangskoeffizient bei erhöhten Prandtl-Zahlen und hohen Reynolds-Zahlen maßgeblich erhöht werden. Der Vergleich der Anlagenkonfigurationen von Alhusseini und Weise zeigt, dass die Rohrlänge den integralen Wärmeübergang ebenfalls beeinflusst. Die Messungen der Fluiddynamik lassen erkennen, dass es im Bereich nach der Filmaufgabe zu einer wellenfreien Zone kommt. Die Länge dieser Zone schwankt stark. Der Mittelwert ist abhängig von der Berieselungsdichte, der Viskosität des Mediums und auch von der Einlaufgeometrie. In einem ersten Modellierungsansatz wurde das Modell nach Alhusseini modifiziert, so dass die experimentellen Daten beschrieben werden. Eine hohe Zahl an Fallunterscheidungen ist nötig, um die experimentellen Daten nach diesem Ansatz wiederzugeben. In einem zweiten Ansatz wurde eine Modellierung durch die Isolierung der Einflussgrößen vorgenommen. Die ermittelten Modellgleichungen beschreiben die experimentellen Ergebnisse stoffunabhängig mit einer Genauigkeit von ±15 %. In the present study the falling film evaporation of pure liquids with increased viscosities and different film inlet geometries is investigated. A stainless steel falling film evaporator with dimensions of di x s x l = 30 x 3 x 2500 mm was used to quantify the heat transfer of water, propylene glycol and cyclohexanol in falling films. Two different weirs, a flat and a slotted weir, were used in the apparatus to investigate the influence of the inlet geometry. Additionally the fluid dynamics in the upper region of a falling film were studied with water and solutions of water/polyvinylpyrrolidone. Fluid dynamics were examined in dependency of the film inlet geometry in a Plexiglas® tube. A computer based analysis of photographs was used to qualify the fluid flow. Results of the heat transfer measurements show that the conventional correlations to predict the heat transfer coefficients by VDI Wärmeatlas [Schnabel et al., 2006, part Md] can not be applied for the calculation of the heat transfer of viscous media. Correlations given by Alhusseini [Alhusseini, 1995] and Weise [Weise, 2007], based on measurements with liquids with increased viscosities, do not describe the integral heat transfer coefficient for the evaporation of propylene glycol and cyclohexanol in the present test rig qualitatively and quantitatively. Heat transfer measurements in this study reveal that the geometry of the test rig, especially the fluid inlet geometry, has a significant influence on the integral heat transfer coefficient for viscous media. Results of the slotted weir show that the heat transfer coefficient can be enhanced significantly at increased Prandtl numbers and at increased Reynolds numbers. A comparsion to the rig geometries from Alhusseini and Weise shows, that the length of the used evaporation tube affects the degree of influence of the fluid inlet geometry. Results from fluiddynamic measurements reveal a wave free zone in the upper region of the tube, though the length of the wave free zone fluctuates. The average length depends on the irrigation rate, the fluid viscosity and on the geometry of the fluid inlet. In a first modelling approach the Alhusseini model is modified to describe the experimental results. However, a high number of different equations is needed to describe the different results for cyclohexanol and propylene glycol as well as the results for the different inlet geometries. Thus a model is developed through the separation of the influence parameters, irrigation rate and viscosity, to describe the heat transfer coefficient. With this model the description of the experimental results with less equations and less complexity is possible.
Dieses Produkt haben wir gerade leider nicht auf Lager.
ab 14,09 €
Derzeit nicht verfügbar
Derzeit nicht verfügbar

Handgeprüfte Gebrauchtware

Bis zu 50 % günstiger als neu

Der Umwelt zuliebe

Technische Daten


Erscheinungsdatum
24.04.2012
Sprache
Deutsch
EAN
9783954040902
Herausgeber
Cuvillier Verlag
Serien- oder Bandtitel
ICTV-Schriftenreihe
Sonderedition
Nein
Autor
Stefanie Arndt
Seitenanzahl
146
Auflage
1
Einbandart
Unbekannter Einband
Bandzählung
13
Schlagwörter
Einlaufgeometrie, viskoser Reinstoffe, Fallfilmverdampfung
Thema-Inhalt
TG - Maschinenbau und Werkstoffe

Warnhinweise und Sicherheitsinformationen

Informationen nach EU Data Act

-.-
Leider noch keine Bewertungen
Leider noch keine Bewertungen
Sicher bei rebuy kaufen
Schreib die erste Bewertung für dieses Produkt!
Wenn du eine Bewertung für dieses Produkt schreibst, hilfst du allen Kund:innen, die noch überlegen, ob sie das Produkt kaufen wollen. Vielen Dank, dass du mitmachst!
Sicher bei rebuy kaufen