Bis zu 50 % günstiger als neu 3 Jahre rebuy Garantie Professionelles Refurbishment
ElektronikMedien
Tipps & News
AppleAlle anzeigen
TabletsAlle anzeigen
HandyAlle anzeigen
Fairphone
AppleAlle anzeigen
iPhone Air Generation
GoogleAlle anzeigen
Pixel Fold
HonorAlle anzeigen
HuaweiAlle anzeigen
Honor SerieY-Serie
NothingAlle anzeigen
OnePlusAlle anzeigen
OnePlus 11 GenerationOnePlus 12 Generation
SamsungAlle anzeigen
Galaxy XcoverWeitere Modelle
SonyAlle anzeigen
Weitere Modelle
XiaomiAlle anzeigen
Weitere Modelle
Tablets & eBook ReaderAlle anzeigen
Google
AppleAlle anzeigen
HuaweiAlle anzeigen
MatePad Pro Serie
MicrosoftAlle anzeigen
XiaomiAlle anzeigen
Kameras & ZubehörAlle anzeigen
ObjektiveAlle anzeigen
System & SpiegelreflexAlle anzeigen
WearablesAlle anzeigen
Fitness TrackerAlle anzeigen
SmartwatchesAlle anzeigen
Xiaomi
Konsolen & ZubehörAlle anzeigen
Lenovo Legion GoMSI Claw
NintendoAlle anzeigen
Nintendo Switch Lite
PlayStationAlle anzeigen
XboxAlle anzeigen
Audio & HiFiAlle anzeigen
KopfhörerAlle anzeigen
FairphoneGoogle
LautsprecherAlle anzeigen
Beats by Dr. DreGoogleYamahatonies
iPodAlle anzeigen

Handgeprüfte Gebrauchtware

Bis zu 50 % günstiger als neu

Der Umwelt zuliebe

New Enhanced Sensitivity Infrared Laser Spectroscopy Techniques Applied to Reactive Plasmas and Trace Gas Detection

Stefan Welzel (Broschiert, Englisch)

Keine Bewertungen vorhanden
Optischer Zustand
Beschreibung
Infrared laser absorption spectroscopy (IRLAS) employing both tuneable diode and quantum cascade lasers (TDLs, QCLs) has been applied with both high sensitivity and high time resolution to plasma diagnostics and trace gas measurements. TDLAS combined with a conventional White type multiple pass cell was used to detect up to 13 constituent molecular species in low pressure Ar/H2/N2/O2 and Ar/CH4/N2/O2 microwave discharges, among them the main products such as H2O, NH3, NO and CO, HCN respectively. The hydroxyl radical has been measured in the mid infrared (MIR) spectral range in-situ in both plasmas yielding number densities of between 1011 ... 1012 cm-3. Strong indications of surface dominated formation of either NH3 or N2O and NO were found in the H2-N2-O2 system. In methane containing plasmas a transition between deposition and etching conditions and generally an incomplete oxidation of the precursor were observed. The application of QCLs for IRLAS under low pressure conditions employing the most common tuning approaches has been investigated in detail. A new method of analysing absorption features quantitatively when the rapid passage effect is present is proposed. If power saturation is negligible, integrating the undisturbed half of the line profile yields accurate number densities without calibrating the system. By means of a time resolved analysis of individual chirped QCL pulses the main reasons for increased effective laser line widths could be identified. Apart from the well-known frequency down chirp non-linear absorption phenomena and bandwidth limitations of the detection system may significantly degrade the performance and accuracy of inter pulse spectrometers. The minimum analogue bandwidth of the entire system should normally not fall below 250 MHz. QCLAS using pulsed lasers has been used for highly time resolved measurements in reactive plasmas for the first time enabling a time resolution down to about 100 ns to be achieved. A temperature increase of typically less than 50 K has been established for pulsed DC discharges containing Ar/N2 and traces of NO. The main NO production and depletion reactions have been identified from a comparison of model calculations and time resolved measurements in plasma pulses of up to 100 ms. Considerable NO destruction is observed after 5 ... 10 ms due to the impact of N atoms. Finally, thermoelectrically (TE) cooled pulsed and continuous wave (cw) QCLs have been employed for high finesse cavity absorption spectroscopy in the MIR. Cavity ring down spectroscopy (CRDS) has been performed with pulsed QCLs and was found to be limited by the intrinsic frequency chirp of the laser suppressing an efficient intensity build-up inside the cavity. Consequently the accuracy and advantage of an absolute internal absorption calibration is not achievable. A room temperature cw QCL was used in a complementary cavity enhanced absorption spectroscopy (CEAS) configuration which was equipped with different cavities of up to 1.3 m length. This spectrometer yielded path lengths of up to 4 km and a noise equivalent absorption down to 4 x 10-8 cm-1Hz-1/2. The corresponding molecular concentration detection limit (e.g. for CH4, N2O and C2H2 at 1303 cm-1/7.66 buch@springer 40 >;
Dieses Produkt haben wir gerade leider nicht auf Lager.
ab 29,99 €
Derzeit nicht verfügbar
Derzeit nicht verfügbar

Handgeprüfte Gebrauchtware

Bis zu 50 % günstiger als neu

Der Umwelt zuliebe

Technische Daten


Erscheinungsdatum
28.11.2009
Sprache
Englisch
EAN
9783832523459
Herausgeber
Logos Berlin
Sonderedition
Nein
Autor
Stefan Welzel
Seitenanzahl
197
Einbandart
Broschiert
Schlagwörter
Quantum Cascade Laser, Plasma Surface Interaction, Plasma Chemistry, Cavity Ring-Down Spectroscopy (CRDS), Cavity Enhanced Absorption Spectroscopy (CEAS)
Thema-Inhalt
PH - Physik
Höhe
210 mm
Breite
14.5 cm

Warnhinweise und Sicherheitsinformationen

Informationen nach EU Data Act

-.-
Leider noch keine Bewertungen
Leider noch keine Bewertungen
Sicher bei rebuy kaufen
Schreib die erste Bewertung für dieses Produkt!
Wenn du eine Bewertung für dieses Produkt schreibst, hilfst du allen Kund:innen, die noch überlegen, ob sie das Produkt kaufen wollen. Vielen Dank, dass du mitmachst!
Sicher bei rebuy kaufen